The China Glass Lined Reaction Tank needs to be tested after long-term disuse.Generally speaking,it is necessary to check whether the mechanical device can operate stably and whether the mixer used in it can be used normally.Another important thing is to check the airtightness of the equipment.Let's take a look at the testing method for equipment airtightness.
1.Need to test the airtightness of the gas transmission pipeline in the device.During testing,ensure that the pressure of the air compression system is above 0.4 megapascals,close the inlet and outlet valves of the chilled water,and then open the glass lined reaction tank of the air compression valve.After increasing the jacket pressure to 0.4 megapascals,stop applying pressure and wait for a period of time to observe if the pressure decreases.If reduced,there will be issues with the sealing performance of the equipment.
2.After the test is completed,it is necessary to add 80%water to the enamel glass reaction tank,start the equipment for stirring,and then add nitrogen gas.At this point,the sealing position can be coated with soapy water to test the sealing performance.If there are no bubbles at the sealed area during observation,the airtightness is better.
The above content is the method for testing the airtightness of glass lined reaction tanks.After the experiment,we can ensure that there are no leaks,and then we can ensure that the materials inside the equipment react well during use.Please continue to follow the dynamic updates for more content.