It is necessary to check the status of the equipment during the start-up of the
China vertical glass lined storage tank.After material input,operators should not hastily start the equipment,but should understand the operating procedures and master the following start-up requirements:
1.Start the mixing operation according to the feeding process operation procedure;
2.During operation,the vertical glass lined storage tank should strictly follow the process operation procedures,and it is strictly prohibited to operate at excessive temperature,pressure,or load.When abnormal situations such as overheating,overpressure,and overload occur,corresponding measures should be taken immediately according to the process regulations.Do not react beyond the specified liquid level in the tank.
3.Strictly follow the feeding ratio specified in the process,balance and control the feeding and heating speed,and prevent severe reactions caused by incorrect or too fast feeding ratios,as well as abnormal situations such as overheating,overpressure,and overload in the vertical glass lined storage tank,which may cause equipment accidents.
4.When heating or cooling the vertical glass lined storage tank,the operation must be stable to avoid sudden superposition of temperature difference stress and pressure stress,which may cause equipment deformation or damage.
5.Strictly implement the handover management system,ensure that the equipment operates smoothly during the handover,and prevent abnormal situations and equipment accidents caused by unclear handover.
The above is an introduction to the start-up requirements for vertical glass lined storage tank,which can improve the safety of equipment use.Operators should carefully understand and avoid emergency shutdown of the equipment after startup.